• Rated power 6KW, power factor 1.0

  • Max.PV array power 4500watt

  • MPPT Voltage range 60VDC-250VDC, 250Voc

  • With Low frequency isolated transformer

  • MAX.DC/AC efficiency up to 94%

  • Low self consumption when no load

  • With AC coupling function

  • AC bypass + inverter mode output max double power

  • Parallel operation up to 6 units

  • WiFi/GPRS remote monitoring (optional)

  • CAN/RS485 communication for BMS

Part 1

Model Sunlenty M6000LS-48SP-M
Rated Power 6KW
System DC Voltage Rated 48VDC, range 40-60VDC
Remote monitoring WiFi/GPRS (optional)
Parallel Option Yes, up to 6 units
Inverter Output
AC Voltage 104V-110V-115V-120VAC/ 208V-220V-230V-240VAC
Surge Power (20ms) 18KW
Peak Efficiency 94%
Self Consumption <20W
Waveform Pure sine wave

Part 2

Solar Charger
Max.PV Array Open Circuit Voltage 250VDC
Max.PV Array Power 4500W
Operating Voltage MPPT Range 60~245VDC
Max.Solar Charge Current 80A
Max.PV Charge Efficiency 97%
    AC Charger  (Grid/Generator)
AC Charge Input Voltage Range 154Vac-260Vac
AC Input Frequency Range 45Hz~65Hz
Max.Grid Charge Current 60A
Protection Overload, Short circuit, Overvoltage, Undervoltage, Overheat
Frequency Range 50Hz/ 60Hz (Auto sensing)
Battery Overcharge Protection AGM: 60V; FLD: 62V; USE: CE+4.0V
    AC Bypass
Max.(AC+PC) Charge Current 140A
Switching Time 10ms
AC Input Voltage Range 154Vac-272Vac (default)
Max.AC Input Current 50A

Part 3

Physical
Dimension 650*365*247mm
Net Weight 38.5kg
Communication Interface CAN/RS485/USB

Part 4

Operating Environment
Humidity 5% to 95% Relative Humidity (Non-condensing)
Enclosure Protection Degree IP20
Altitude <2000m
Operating Temperature 0~50
Storage Temperature -40~60