• Rated power 6KW, power factor 1.0

  • 2 strings of MPPT, Max.PV array power 8000watt

  • MPPT Voltage range 120VDC-450VDC, 500Voc

  • Built-in ATS for automatic grid and generator switching

  • Built-in anti-dust kit for harsh environment

  • MC4 PV input connector

  • Parallel operation up to 6 units

  • WiFi/GPRS remote monitoring (optional)

  • Able to work with or without battery

  • CAN/RS485 communication for BMS

Part 1
Model M6000HX-48-BP
Rated Power 6KW
System DC Voltage 48VDC
Parallel Option Yes, up to 6 units
Remote monitoring WiFi/GPRS (optional)
Inverter Output
AC Voltage 220V-230V-240VAC
Surge Power 12000VA
Peak Efficiency 94%
Transfer Time
10ms(For Personal Computers)
20ms(For Home Appliances)
Waveform Pure Sine Wave
Self Consumption 70watt
Part 2
Solar Charger
Type of PV Array Input Terminal MC4
Max.PV Array Open Circuit Voltage 500VDC
Max.PV Input Current/ Per String 16A
Number of PV Array Input 2 Strings
Max.PV Array Power Each String:4000watt; Total 8000watt
Operating Voltage MPPT Range 120~450VDC
Battery Overcharge Protection 60VDC
Max.Solar Charge Current 100A
    AC Charger (Grid/Generator)
Max.Grid Charge
Current
80A
Max.(AC+PC) Charge Current 100A
Frequency Range 50Hz/ 60Hz (Auto sensing)
Protection Overload, Short circuit, Overcurrent, Overvoltage, Undervoltage, Over-Frequency, Under-Frequency, Overheat, Lightning, Surge Power
Part 3
Physical
Dimension 460*395*132mm
Net Weight 13.5kg
Communication
Interface
CAN/RS485/USB
Part 4
Operating Environment
Humidity 5% to 95% Relative Humidity (Non-condensing)
Altitude <2000m
Operating Temperature 0℃~50℃
Storage Temperature -15℃~60℃
Noise <60db
Certificate CE, IEC62109-1,IEC62109-2, UKCA